Role of ultrasound and contrast-enhanced ultrasound in patients with cerebrovascular disease
Explorations Fonctionnelles Cardio-Vasculaires, Hôpital Cardiologique, Lille, France
* Correspondence: Dr Ghislaine Deklunder, CHU Hopital Cardiologique, EFCV, Boulevard du Prof. Leclerq, 59037 Lille, France.
Abstract
Sonography is recognized as the best screening tool for detecting carotid artery stenosis. Nevertheless, cervical ultrasound examination is subject to practical limitations in some rare circumstances. Transcranial sonography is now included in the evaluation of patients with suspected cerebrovascular disease, but attenuation of the ultrasound signal by the skull is common. Contrast agents are known to amplify the reflection of ultrasonic energy and to improve the signal : noise ratio. They can in most cases compensate for the shortcomings encountered in the ultrasound cerebrovascular examination. They are safe and well tolerated. In difficult situations they allow an accurate grading of carotid stenosis and an improved assessment of the intra-cranial arteries. They also enlarge the role of transcranial Doppler.
Key Words: Carotid artery disease contrast media transcranial Doppler ultrasound
References
- Rothwell PM, Warlow CP. Prediction of benefit from carotid endarterectomy individual patients: a risk-modelling study. Lancet. 1999;353:21052110[CrossRef][ISI][Medline]
- Bazzocchi M, Quaia E, Zuiani C, Moroldo M. Transcranial doppler: state of the art. Eur J Radiol. 1998;27(suppl 2):S1415148
- Deklunder G, Gautier C, Custoza E. Contrast agents and carotid artery stenosis. [in French]Journal d'Echographie et de Medicine par les Ultra sons. 1998;19:426430
- Kaps M, Schaffer P, Beller KD, et al. Transcranial echo contrast studies in healthy volunteers. Stroke. 1995;26:20482052
[Abstract/Free Full Text] - Albrecht T, Urbank A, Mahler M, et al. Prolongation and optimization of doppler enhancement with a microbubble US contrast agent by using continuous infusion: preliminary experience. Radiology. 1998;207:339347
[Abstract/Free Full Text] - Uggowitzer M, Kugler C, Riccabona M, et al. Cerebral arteriovenous malformations: diagnostic value of echo-enhanced transcranial doppler sonography compared with angiography. Am J Neuroradiol. 1999;20:101106
[Abstract/Free Full Text] - Correas JM, Burns PN, Lai X, Qi X. Infusion versus bolus of an ultrasound contrast agent: in vivo dose-response measurements of BRl. Invest Radiol. 2000;35:7279[CrossRef][ISI][Medline]
- Bokor D. Diagnostic efficacy of Sono Vue. Am J Cardiol. 2000;86:1924[Medline]
- Kaps M, Seidel G, Bokor D, et al. Safety and ultrasound enhancing potentials of a new sulfur hexafluoride-containing agent in the cerebral circulation. J Neuroimaging. 1999;9:150154[ISI][Medline]
- Campani R, Calliada F, Bottinelli O, et al. Contrast enhancing agents in ultrasonography: clinical applications. Eur J Radiol. 1988;27:S1615170[CrossRef]
- Basseau F, Grenier N, Trillaud H, et al. Doppler frequency shift and time-domain velocity enhancement induced by an ultrasonographic contrast agent. J Ultrasound Med. 2000;19:171176[Abstract]
- Khan HG, Gailloud P, Bude RO, et al. The effect of contrast material on transcranial doppler evaluation of normal middle cerebral artery peak systolic velocity. Am J Neuroradiol. 2000;21:386390
[Abstract/Free Full Text] - Gutberlet M, Venz S, Zendel W, et al. Do ultrasonic contrast agents artificially increase maximum doppler shift? In vivo study of human common carotid arteries. J Ultrasound Med. 1988;17:97102
- Melany ML, Grant EG, Farooki S, et al. Effect of US contrast agents on spectral velocities: in vitro evaluation. Radiology. 1999;211:427431
[Abstract/Free Full Text] - Droste DW, Jürgens R, Nabavi DG, et al. Echocontrast-enhanced ultrasound of extracranial internal carotid artery high-grade stenosis and occlusion. Stroke. 1999;30:23022306
[Abstract/Free Full Text] - Sitzer M, Fürst G, Siebler M, Steinmetz H. Usefulness of an intravenous contrast medium in the characterization of high-grade internal carotid stenosis with color Doppler-assisted duplex imaging. Stroke. 1994;25:385389[Abstract]
- Otis S, Rush M, Boxajian R. Contrast-enhanced transcranial imaging; results of an american phase-two study. Stroke. 1995;26:203209
[Abstract/Free Full Text] - Furst G, Saleh A, Wenserski F, et al. Reliability and validity of noninvasive imaging of internal carotid artery pseudo-occlusion. Stroke. 1999;30:14441449
[Abstract/Free Full Text] - Holden A, Hope JK, Osborne M, et al. Value of a contrast agent in equivocal ultrasound studies: pictorial essay. Australas Radiol. 2000;44:253260[CrossRef][Medline]
- Gautier C, Deklunder G, Leclerc X, et al. Diagnosis management of subocclusive disease of the carotid artery. [in French; abstract]Arch Mal Coeur Vais. 2000;93:1257A
- Haggag K, Russel D, Brucher R, et al. Contrast enhanced pulsed doppler and coulor-coded duplex studies of the cranial vasculature. Eur J Neurol. 1999;6:443448[CrossRef][ISI][Medline]
- Gerriets T, Seidel G, Fiss I, Kaps M. Contrast-enhanced transcranial color-coded duplex sonography: efficiency and validity. Neurology. 1999;52:11331137
[Abstract/Free Full Text] - Droste DW, Jürgens R, Weber S, et al. Benefit of echocontrastenhanced transcranial color-coded duplex ultrasound in the assessment of intracranial collateral pathways. Stroke. 2000;31:920923
[Abstract/Free Full Text] - Griewing B, Motsch L, Piek J, et al. Transcranial power mode doppler duplex sonography of intracranial aneurysms. J Neuroimaging. 1998;8:155158[CrossRef][ISI][Medline]
- Delcker A, Turowski B. Diagnostic value of three-dimensional transcranial contrast duplex sonography. J Neuroimaging. 1997;7:139144[ISI][Medline]
- Klötzsch C, Bozzato A, Lammers G, et al. Three-dimensional transcranial color-coded sonography of cerebral aneurysms. Stroke. 1999;30:22852290
[Abstract/Free Full Text] - Postert T, Muhs A, Meves S, et al. Transient response harmonic imaging. An ultrasound technique related to brain perfusion. Stroke. 1998;29:19011907
[Abstract/Free Full Text] - Itoh T, Matsumoto M, Uchimoto R, et al. Perfusion imaging of the brain by B-mode ultrasonography. An experimental study in rabbits. Stroke. 1995;26:23532357
[Abstract/Free Full Text] - Puls I, Becker G, Maurer M, Mullges W. Cerebral arteriovenous transit time (CTT): a sonographic assesment of cerebral microcirculation using ultrasound contrast agents. Ultrasound Med Biol. 1999;25:503507[CrossRef][ISI][Medline]
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||