Skip Navigation

This Article
Right arrow FREE Full Text (PDF) Freely available
Right arrow References
Right arrow E-letters: Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when E-letters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrow Disclaimer
Right arrow Request Permissions
Google Scholar
Right arrow Articles by Morganroth, J.
Right arrow Search for Related Content
PubMed
Right arrow Articles by Morganroth, J.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?


Focus on issues in measuring and interpreting changes in the QTc interval duration

J. Morganroth*

University of Pennsylvania, eResearch Technology, Philadelphia, U.S.A.

* Correspondence: Joel Morganroth, MD, Clinical Professor of Medicine, University of Pennsylvania, eResearch Technology, 30 S. 17th Street, Philadelphia, PA 19103, U.S.A.

Abstract

Subtle changes on the ECG associated with reports of sudden death produced by non-cardiac drugs, has forced regulatory authorities to be extremely sensitive to ECG findings in drug development programmes. These concerns require pharmaceutical sponsors to re-evaluate their preclinical screening programmes and to consider risk-benefit analyses of continuing a drug's development depending on the electrophysiological effects uncovered. Furthermore, during clinical testing, the non-rigorous, site-specific, and largely uncontrolled methods for performing and analysing ECGs that are currently practised should now be reconsidered. Current methods, which lack standards for interpretation, and yield poor quality data, increase the subsequent risk of false positive or false negative ECG safety results. False positive data may result in a drug not receiving regulatory approval (or the sponsor having to perform additional expensive clinical trials or retrospective reviews of existing ECG data). More worrisome are false negative studies which result in approval followed by unexpected cardiac toxicity (when the drug is taken by a larger and uncontrolled patient population) and ultimately withdrawal from the market. The economic consequences of either of these outcomes are not acceptable. Core ECG laboratories, with cardiovascular expertise, state-of-the-art information management technologies, and ECG reading systems, which are validated, quality assured, and constantly audited, can cost-effectively manage a product's entire ECG safety programme. Finally, with all ECG data residing in one unified database, the validation and integration of clinical research data can be completed more rapidly with consequent dramatic reductions in the time required to prepare an NDA and ultimately gain regulatory approval.

Key Words: QTc interval • ECG • drug development • drug safety • clinical trial design


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?


This article has been cited by other articles:


Home page
J Clin PharmacolHome page
N. Sarapa, S. F. Francom, S. M. Azzam, P. K. Wickremasingha, and B. Tyl
Detection of Clinically Significant QTc Prolongation in Phase I Studies in Healthy Participants: Comparison of 2 Semiautomated QT Measurement Methods
J. Clin. Pharmacol., January 1, 2009; 49(1): 103 - 108.
[Full Text] [PDF]


Home page
J Clin PharmacolHome page
N. Sarapa, J. L. Mortara, B. D. Brown, L. Isola, and F. Badilini
Quantitative Performance of E-Scribe Warehouse in Detecting Quality Issues With Digital Annotated ECG Data From Healthy Subjects
J. Clin. Pharmacol., May 1, 2008; 48(5): 538 - 546.
[Abstract] [Full Text] [PDF]


Home page
Eur Heart JHome page
H.J. Koch and C. Raschka
Ultradian diurnal variations of QTc and relevant cardiovascular characteristics should be considered with regard to risk assessment
Eur. Heart J., February 2, 2002; 23(4): 341 - 342.
[Full Text] [PDF]



Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.